The T100 Series Mechanical Time Switch has proven it can stand the test of time. These dependable time switches can handle electrical loads up to 40 A per pole and allow for up to 12 ON/OFF operations per day. Intermatic T100 Series Mechanical Time Switches Deliver Long-Lasting Value. Insulator for Single-Pole Time Switch (T101, T102. View and Download Intermatic EJ600 Series installation and user manual online. Digital In-Wall Astronomic Timer. EJ600 Series Timer pdf manual download. Intermatic HB114C Timer, 240-Volt, White. 3.7 out of 5 stars 123. Get it as soon as Fri, Nov 29. FREE Shipping on orders over $25 shipped by Amazon. Canon eos 1 n user manual 2017. More Buying Choices $19.00 (6 new offers) Intermatic HB880R 15-Amp Outdoor Digital Timer for Control of Lights, Decorations, Pumps or Fans with Astronomic Self Adjust.
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• Installation and/or wiring must be in accordance with national and local electrical code requirements.
• This enclosure does not provide grounding between conduit connections.When metallic conduit is used, you must also install grounding type bushings and jumper wire.
• Use #14-#12 AWG wires, rated at least 75°C (167°F)-COPPER conductors ONLY.
• If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
• Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
• Do not remove insulator that is covering terminals.
• KEEP DOOR CLOSED AT ALL TIMES when not servicing.
• Do NOT touch circuit board components. Contact can create a static discharge, which can damage the microprocessor.
The Intermatic DT101 Digital 24-Hour Time Switch automatically switches loads to a preset daily schedule with to-the-minute
accuracy. Use the DT101 as an ON/OFF timer in applications requiring 24-hour load control such as lighting, air conditioning
systems, pumps, etc. Each load output of the Time Switch can support up to 14 timed ON and 14 timed OFF events per day.
The program can be overridden by pushing the ON/OFF load override button(s). The DT101 Time Switch is designed to directly
switch tungsten or ballast loads up to its rating, and inductive or resistive loads up to 20 A at 120, 208, 240 or 277 VAC.
Time Switch
• Power Consumption: 6.0 W Max.
Switch Ratings
• 20 A Ballast, 120-277 VAC, 60 Hz
• 5 A Tungsten: 120/240 VAC, 60 Hz
• 2 HP, 240 VAC, 60 Hz
Intermatic Timer T100 User Manual Pdf
• The load output of the Time Switch can support up to
Battery-Powered Clock Operation
alkaline nonrechargeable 1.5 V batteries, supplied)
Intermatic Timer T100 User Manual Download
• 1 minute
• 23 hours, 59 minutes
• 2.5 lb. (1.1 kg)
• TYPE 1 indoor metal enclosure
• Combination 1/2-3/4' size (one on back, one on each